Regulator Rectifier|high Voltage Rectifier ZHS-45000A/670V for Electrochemical

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-11-05 01:23
Browse the number: 399
inquiry
Company Profile
 
 
Product details

The High Current Rectifiers listed on this website is customized, just for your reference. If you have any specific demands,please tell us the parameters in details. We’ll be more than happy to work with you to meet your exact requirements.

The main parameters of our Thyristor / Diode High Current Rectifiers for Industrial Applications:

A)Voltage Specification:  5V - 3000V

B)  Current Specification:  300A - 240000A

C)  Output Current Adjusting Range: 0 - 1000A

Technical Parameters


Model

ZHS-45000A/670V

Efficiency

≥99.4%

Input Voltage

AC35KV

Rated Voltage

DC670V

Input Current

AC96A

Rated Current

DC45000A

Range of Regulation

 

On-load Voltage + Switch  Regulation: 15%-105% Udn

Notes for Order

 

Input Voltage

AC300V-330KV

Optional

Frequency

40-60Hz

Optional

Current Regalation


Optional

Voltage Regulation


Optional

Rated Current


Optional

Rated Voltage


Optional

Cooling Mothed

Water,Air,natural or Forced

Draft Cooling

Optional


Digest of High Current Rectifier(HCR)technical documents.

Part fourteen of User Manual

Fourth part of Chapter V

Chapter V: Rectifying Automation Monitoring System

4.6 Sound-light alarm of event and fault

Pop up the corresponding alarm window and make different sound prompts in case of operation, login event, status change and fault in the system.


4.7 System operation safety management

Multilevel authorized operation management mode can be designed in the system according to the user's production management needs.

5. Monitoring system software operation

5.1 Login

5.2 Real-time conditions

When the main interface of the monitoring system is entered for the first time, the default monitoring main screen is the real-time conditions screen, as shown in Figure 3.

The main interface of ZK-200 rectifying automation monitoring system is mainly composed of the main menu and main monitoring screen.

5.3 Main menu

At the top of the main interface of the monitoring system is the main menu screen, as shown in Figure 4. 

  

Conduct following operation in the main menu screen:

: Click this button or the icon above to enter the real-time conditions screen.

: Click this button or the icon above to open the quik-fuses states window.

: Click this button or the icon above to enter the fault query screen.

: Click this button or the icon above to open the real-time alarm table and historical alarm table window.

:   Click this button or the icon above to open the operation record window.

: Click this button or the icon above to open the real-time trend chart and trend chart window.

Click this button or the icon above to open the production statement window.

5.4 Main wiring diagram

In the middle of the real-time conditions screen is the main wiring diagram screen, as shown in Figure 6.

5.5 Rectifier unit operation monitoring

Click the button in the left of the real-time conditions screen to enter the operation monitoring screen of 1# rectifier unit, as shown in Figure 7.

The operation monitoring screen of 1# rectifier unit has the main functions as follows:

1) Display the main wiring diagram of the rectifier unit system.

2) Display the real-time analog quantity: DC voltage, DC current, on-load gear and conduction angle.

3) Display real-time working status of all equipment in the rectifier system.

4) Operate the rectifier control cabinet, on-load switch and other equipment.

The operation is as follows:

① On-load switch operation

Click the button to pop up the window as shown in Figure 8. 

The operating authorization for the on-load switch must be greater than 200.

② Rectifier operation

       Start conditions of rectifier: no total fault or repeated fault.Click the button to pop up the following dialog box for secondary confirmation of rectifier start. 

Click the button to pop up the following dialog box for secondary confirmation of rectifier stop.

5) Rectifier unit current setting adjustment 

Click the given current in the figure to pop up the value input box. Input the required current value and press Enter key. The current quickly rises to the given current value.

Current fine tuning operation method: set the lifting/falling current value each time and then click the current up/down button to increase and decrease the current, as shown below

5.6 Immediate event alarm window

In case of new event, the system pops up the window, as shown in Figure 14 and issues the event sound. Click the button         in the screen to eliminate the sound.   


In case of fault, the system pops up the window, as shown in Figure 15 and issues the event sound. Click the button in the screen to eliminate the sound. Click the button to enter the fault query window    

6. Real-time data

7. Fault query

Click the button or the icon in the main menu to enter the fault alarm screen, as shown in Figure 17.

In case of fault, the light indicator of the corresponding fault turns red. Click the button [复位] to reset the fault when the fault disappears.

8. Alarm record

8.1 Real-time alarm form

Click the button          icon   in the main menu to open the real-time alarm form window, as shown in Figure 18.

This form lists all events, faults, occurrence time and other information currently existing in the system. The events and faults, if not confirmed by the operator, are fully in red and, if confirmed, turn to blue and the confirmation time and date are displayed.

8.2 Historical alarm form

Click the button            in the real-time alarm form window to open the historical alarm form window, as shown in Figure 19. 

Click the buttonto    query all fault alarm and event alarm records of the system.

Click the icon               to print the query content displayed in the window

9. Operation record

Click the button                  in the main menu to open the operation record screen window, as shown in Figure 20.

This form can be used to query all historical operation records in the system.

Click the date control to select the date.

Click the query display button to select the query mode and display the content to be queried.

Click the icon to print the query content。  

10. Trend chart

10.1 Real-time trend chart

Click the button              in the main menu to open the real-time trend chart window, as shown in Figure 21.

This window can display the real-time curve of all analog quantities.

Curve selection method: click           the button to select the curve to be displayed. 

10.2 Historical trend chart

Click the button            in the real-time trend chart to open the historical trend chart window, as shown in Figure 22.

The main functions and operation of the historical trend chart are as follows:

① Choose to display the historical curve of various analog quantities respectively and simultaneously.

② Choose the time quantum to display the curve.

③ Query the analog quantity at any time.

④ Query the average value from the initial section to the end section.

⑤ Print the displayed curve.

11. Production statement

Click the button            in the main menu to open the production statement window, as shown in Figure 23.

Query the daily statement data of all analog quantities of the rectifier unit within recent year in this window.

Query method: click the date choice box to select the date and display the daily statement to be queried.

Click the icon to print the query content。. 

12.User login

Click the button  to pop up the login screen window, as shown in Figure 8.

Enter the correct username and password to log in successfully.

13.User logout

Click the button to log out.

14. Monitoring system software installation

14.1 Hardware requirements:

    1. INTEL machine and its compatible machine

2. VGA, SVGA and graphic display card supporting Windows256 colors

3. Basic frequency above 100MHZ, memory no less than 1G and hard disk no less than 20G

4. Runtime environment: Windows 7

14.2 Installation steps:

1. Install the operating system Windows xp

2. Install the configuration software.

3. Install the monitoring system project documents

The application program project documents of ZK-200 rectifying automation monitoring system include monitoring software and database installed in D disk. The specific operation is as follows:

1) Monitoring software installation

Installation path: D:\yilang

The system has been backed up. Make one-key reset of the system after system destruction to copy the backup monitoring software in the path of D disk. The project can be recovered to normal operation.

2) Database installation

Installation path: E:\yilang

Database mainly stores: ① Various historical data in operation of the monitoring system

② Alarm window database documents

③  Event and alarm ring

④  Operator document

3) Define the data source

① Enter the control panel in Windows 7system.

② Double click the management tool icon.

③ Double click the data source (ODBC) icon.

④ Select the user DSN and click Add to open the new data source window.

⑤ Select Microsoft  Access  Driver (﹡.mdb) and click Finish to open ODBCMicrosoft  access installation window.

⑥ Enter the data source name "yl' and click Select to open the selected database window.

⑦ Select the path: E:\yilang\Alarm。

⑧ Click OK and close the selected database window.

⑨ Click OK and close ODBCMicrosoft  access installation window.

⑩ Click OK, close ODBC data source manager window and complete data source definition.

Double click the icon on the desktop to pop up the project manager window. Select the project China National Salt Industry automatic monitoring system to be run and then click the run icon in the project manager to enter ZK-200 rectifying automation monitoring system.

15. Click the button [Login] in the main menu of monitoring system to enter the Uers management screen.



High Current Rectifier(HRC)ZHS-45000A/670V Structure Feature & Advantages

▲ Adopted cophase counter parallel connection Rectification,wihich can increase the power factor and reduce power loss

▲ Three-phase bridge rectification,which has the characteristics of reliability,stability,and low losses

▲ Adopted aluminum frame and glass antimagnetic cabinet, which suit for monitor and maintenance

▲ Power is scalable

▲ Can be maintained with electricity.

▲ With Low noise 

▲ Easy to operate 

▲ Superiority of Ture Rdundancy technique

▲Over / low Voltage protection    

▲Over / low current protection   

▲Over / lack water protection        

▲Over temperature protection

▲Fast fuse protection      

▲Phase protection  

 

Our products of High Current Rectifier (HRC) are customized according to clients’s parameters.They are used in variety of applications as follows:

1.Plating: Chrome, Zine, Nickel, Copper, Gold, Silver

2.Metal smelting: Aluminum, Copper,  Zine, Lead, Manganese, Magnesium, etc.

3.Ionic membrane: Electrolysis of salt, etc

4.Silicon carbide smelting & Graphitization furnace

5.Experimental power supply

6.Copper foil, aluminum foil special power supply

7.Electrochemical: Chlor-alkali, etc

8.Electrolysis: Copper, Zine, Tin, Lead, Aluminum foil, Copper foil

 

The expert teams with 20 years experience can supply equipment design,manufacture, upgrading and after sales service. It’s quality management system meets the requirement of the ISO9001:2008 standard. The Technical level of main equpment is ten years ahead in China,and the control system is twenty years ahead at home and abroad.

We service with pride and care and give you a best solution. 

 Packing Details:In iron sheet case with waterproof and anti collision treatment

Delivery Details: 1-3 months, depending on your technical parameters

 

Please give us the follows technical information before order:

1  A.C. INPUT

• A.C: rated voltage

• Phases

• Frequency

2  D.C. OUTPUT

• Rated D.C. voltage

• Rated D.C. current

• D.C. voltage fine control range (thyristors)

• D.C: current control range

• Accuracy of current fine control

• Pulse number

• Ripple

1. Within the first year, if you need any spare parts for replacement, we can provide to you without

paid. And we will offer lifelong technical support and service.

 

2. Within the first year, if you need any spare parts for replacement, we can provide to you without

paid. And we will offer lifelong technical support and service.

 

 

1.Q:Are you a factory or trading company?
A: We are a factory.

 

2. Q: Where is your factory? How can I visit there?

A: Our factory is located in Xi’an, middle part of China, about an hour bus ride from Xi’an Xianyang Airport, which in the starting point of Ancient Silk Road.Welcome to visit us.

 

3. Q:When can I get the price?

A:Usually we quote within 24 hours after we get your inquiry.


Total0bar [View All]  Related Comments
 
more»Other products